Purifying workshop
|
There are two sets of air-condition
system in the workshop. Fresh air is filtrated twice before
sending into each purified room 20 times an hour. The Environmental
standard of purified room is as follow: temperature: 18~26?;
relative humidity: 50~65%; air in-taking speed: greater
than 0.25m/s; pressure difference: greater than 10Pa , particles
in air greater than 0.5µm: Less than 3500 per liter.
In accordance with GB 15980-1995 standard, bacteria number
is reduced by ozone antisepsis to less than 500cfu/m3 in
the purify room and less than 10 cfu/cm2 on the worktable.
|
All employees
have to go through two dressing rooms, hand disinfector
and auto air shower before getting into purify room which
is rated eight at ISO standard. Bacteria number on any hand
of filling worker should not be greater than 300 cfu in
accordance with GB15980-1995 standard.
|

Auto air shower and hand disinfection
|

Antisepsis
|
Antisepsis department will sterilize cosmetic
package. All glasses must be dip in disinfector for 40 minutes,
flushed by asepsis-water, then dried at 115oC for 45 minutes.
Other plastics, tubes, cushions and toppers must be sterilized
by ethylene oxide for 4.5 hours with concentration at 600~700
mg/L, negative pressure at 60 KPa. Bacteria number should
not be greater than 10 cfu after sterilization. |
The water handling facilities
adopt mechanical filtrate, active carbon filtrate, minutely
filtrate, two rate reverse osmosis and ultraviolet radiation
irradiation. The conductance of purify water should not
be greater than 2.1µs/cm (25±1?) and bacteria
number should not be greater than 10 cfu/ml. The quality
of purify water is only secondary to that of medical injection
water. |

Water handling facilities
|

Warehouse
|
The warehouse is equipped
with ANCC---internationally acknowledged bar-code system
and tailor-made ERP software so as to facilitate the conveyance
of the goods. The warehouse setting, conforming to international
standard, can effectively protect the belongs of our clients
and allows them to pay more attention to the product marketing
and expansion of the market share, thus can enhance our
image among our clients.
|
Quality Control Center is
responsible for quality control, research and development
of new products as well as monitoring development trend
of IFSCC and ICR. Full range of experiment and inspection
equipments can perform freeze and melt, jolting and destroying
test. |

Quality Control Center
|
|
|
|