: : : : : : Manufacturing Process : : : : : : : : : : : : Production Facility : : : : : :

Purifying workshop

There are two sets of air-condition system in the workshop. Fresh air is filtrated twice before sending into each purified room 20 times an hour. The Environmental standard of purified room is as follow: temperature: 18~26?; relative humidity: 50~65%; air in-taking speed: greater than 0.25m/s; pressure difference: greater than 10Pa , particles in air greater than 0.5µm: Less than 3500 per liter. In accordance with GB 15980-1995 standard, bacteria number is reduced by ozone antisepsis to less than 500cfu/m3 in the purify room and less than 10 cfu/cm2 on the worktable.
All employees have to go through two dressing rooms, hand disinfector and auto air shower before getting into purify room which is rated eight at ISO standard. Bacteria number on any hand of filling worker should not be greater than 300 cfu in accordance with GB15980-1995 standard.

Auto air shower and hand disinfection


Antisepsis

Antisepsis department will sterilize cosmetic package. All glasses must be dip in disinfector for 40 minutes, flushed by asepsis-water, then dried at 115oC for 45 minutes. Other plastics, tubes, cushions and toppers must be sterilized by ethylene oxide for 4.5 hours with concentration at 600~700 mg/L, negative pressure at 60 KPa. Bacteria number should not be greater than 10 cfu after sterilization.
The water handling facilities adopt mechanical filtrate, active carbon filtrate, minutely filtrate, two rate reverse osmosis and ultraviolet radiation irradiation. The conductance of purify water should not be greater than 2.1µs/cm (25±1?) and bacteria number should not be greater than 10 cfu/ml. The quality of purify water is only secondary to that of medical injection water.

Water handling facilities

Warehouse

The warehouse is equipped with ANCC---internationally acknowledged bar-code system and tailor-made ERP software so as to facilitate the conveyance of the goods. The warehouse setting, conforming to international standard, can effectively protect the belongs of our clients and allows them to pay more attention to the product marketing and expansion of the market share, thus can enhance our image among our clients.
Quality Control Center is responsible for quality control, research and development of new products as well as monitoring development trend of IFSCC and ICR. Full range of experiment and inspection equipments can perform freeze and melt, jolting and destroying test.

Quality Control Center